Power Supply 3 AMPS 12V Access Control
$58.25
$104.27
POWER SUPPLY 3 AMPS 12V ACCESS CONTROL Input Voltage: AC200V-240V Output Voltage: DC12V Instantaneous current: 3A Continuous Current: 1.2A Working Temperature: -20ðC~60ðC Operating Humidity: = 90%RH Features: â High Efficiency and good price â Built-in EMI filter -100% full load burn-in test â Low output ripple and noise â Protection:Over load/Over voltage/Short circuit â With protective circuit â Output: 12V,5A 12VDC â Capable to connect with 12V 7AH backup battery specifications Input Voltage: 110VDC/220VAC 10%;50/60HZ Output Voltage: DC12V/3A Time Relay: 0~15sec. Output Contact: Access control, Electric Lock, Release Button Optional Accessories: Backcup Battery, 12V/7H Standard Design: Steel Materail, Painted Protect Safely: Short Circuit protection Suitable For : Access control, Electric lock Uninterruptible PSU Metal Case With Key-lock 85% High efficiency 2 Years Warranty Full Protection · No delay battery boot up · 100% full load burn-it test FPS 1203N-01B is an UPS power supply, its main output is 13.6V / 3A, while it also provides maximum 1A charge current. It could be used for CCTV surveillance / access control / fire alarm and other security systems. Work with different optional modules INPUT Voltage Range 190 â 240VAC Frequency Range 50 â 60Hz OUTPUT Voltage (AC Mode) 13.6V ±2% Voltage (Battery Mode) Same as battery voltage Rated Current 5A Rated Power (Max.) 77.5W (with 0.7A charge current) Efficiency (Typ.) >85% Ripple & Noise <120mVp-p Output Channel 4 channel CHARGING Voltage 13.6V ±2% Current 0.7A, Constant current PROTECTION Input 3A / 250VAC fuse Overload 6A ±5%: Hiccup mode, recovers automatically after fault condition is removed. Over Voltage 16V ±5%: Hiccup mode, recovers automatically after fault condition is removed. Short Circuit Hiccup mode, recovers automatically after fault condition is removed. Battery Low Voltage 10V ±2%: PSU shuts down until AC power recovers. Battery Reverse Connect Battery not works, no effect on main output. ENVIRONMENT Temperature Working: -20 â 50â Storage: -30 â 80â Humidity Working: 20 â 80%RH Storage: 10 â 90%RH LED INDICATOR Red On AC power is on Green On DC output is on Yellow Off: Battery is fully charged or no battery Flickering: Battery is charging SAFETY & EMC EMC Standards EN 55022: 2010, EN 55024: 2010, EN 61000-3-2: 2014, EN 61000-3-3: 2013 LVD Standards EN 60950-1: 2006 A11: 2009 A1: 2010 A12: 2011 A2: 2013 METAL BOX & PACKING Default Metal Box 265 x 195 x 75mm, fits for 1 pc 12V 10Ah battery. Optional Metal Box 295 x 195 x 90mm, fits for 1 pc 12V 20Ah battery. CTN Size / Weight 42.5 x 39.5 x 30cm / CTN, 16kg / CTN, 10pcs / CTN (default metal box) Category: Access Control
Access Control