SPAAR-VOOR-EURIES.NL ≡ Cream Jar Compact Lip Gloss Tube 3
  • Fire Alarm System

  • Asenware 4 Zone Fire Alarm Control Panel

Asenware 4 Zone Fire Alarm Control Panel

$64.65 $93.1
Asenware 4 Zone Fire Alarm Control Panel The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of a conventional fire alarm system, designed for applications requiring a smoke detector, bell, manual pull stations, and sprinkler. 4 Zone Fire Alarm Control Panel Specification1. It is a modularized design, the panel can expand from 1 zone to 32 zones easily.2. It has 2 level control mode by a lock3. It has 24VDC and 5VDC power supply output.4. It has FIRE and FAULT signal output.5. It has 2 general sounders output.6. Each zone has 1 circuit detectors input7. Each zone can be disabled by a button.8. It has a RESET button to reset the panel.9. It has a SILENCE button to stop BUZZER and SOUNDERS.10. It has EVACUATE button to start a manual fire alarm immediately.11. It has a battery low protection function when battery voltage lower than 21VDCthe battery will be cut off automatically until the mains power is on.12. It has an optional GSM module for fire alarm by SMS Technical parameters AC INPUT 220VAC 50HZ 10% -15% DC OUTPUT 24VDC typical Voltage for MCU 5V for power board MCU, 3.3V for others Current at 24VDC from PSE 450mA standby current Maximum current from PSE 2A except batteries charge Batteries current 1.85A maximum, current limited Auxiliary output 24VDC /- 10%, 100 mA max, current limited, monitored Batteries 2*12V/ 2.3Ah sealed lead acid gel, self-regulated 2*12V/ 7Ah if needed Battery replace Resistance 2Ω±10% if needed Battery low-voltage protection 22.2V Detectors connection allowed each zone 20 (except MCPs) Zone alarm current 6mA minimum/ 27mA maximum Sounder output 2*0.75A maximum Fire protection 100mA maximum Fire routing 100mA maximum Fault routing 100mA maximum Communication protocol 2 wires RS485 bus system Relay contacts rating Dry contacts (NO/NC) 1A @24VDC EOL resistor for zone 6.8K 1W EOL resistor for outputs 6.8K 1W Fuse on power board 3A/ 250V glass tube fuse 20mm Fuse on EMI board 1A/ 250V glass tube fuse 20mm Environmental Class A temperature range: -5 to 40°C (23~104°F) Humidity: 5 to 95% RH, non-condensing Terminal blocks rating All terminals rated for 12 to18 AWG (0.75 to 2.5 mm2) Categories: Fire Panel, Conventional Fire Alarm System
Fire Alarm System

Fire Alarm System

  • Cooper Menvier FX2208CFCPD Conventional 8 Zone Control Panel
    $48.68 $73.51
  • Cooper Menvier Conventional 2 zone Fire Panel
    $43.57 $55.33
  • Cooper Menvier CF30004G Intelligent Addressable 4 Loop Control Panel
    $69.5 $83.4
  • Asenware 4 Zone Fire Alarm Control Panel
    $64.65 $93.1
  • Cooper Menvier CAH330 Intelligent Addressable Multi-Mode Heat Sensor
    $64.97 $122.14
  • Menvier Conventional Smoke Detector with Base
    $37.09 $68.62
  • Asenware Smoke Detector AW-CSD311
    $59.23 $95.95
  • Menvier Conventional Heat Detector with Base
    $57.18 $81.2
  • AW-D316 CONVENTIONAL SOUNDER BEACON
    $64.4 $98.53
  • Cooper Menvier 1 Loop Addressable Panel
    $38.92 $56.04
  • Menvier Conventional combined Fire Alarm Sounder and Strobe Light at 100dB(A) Max at 1m complete with mounting base
    $69.5 $125.8
  • Menvier Addressable Sounder Beacon CAS 381
    $47.91 $88.63
  • Menvier Call Point addressable CBG 370S
    $38.7 $69.27
  • Menvier Conventional Manual Call Point
    $52.56 $71.48
  • Cooper Menvier CAP320 Intelligent Addressable Optical Smoke Sensor
    $46.19 $62.36
  • Cooper Menvier CBG870 Addressable Manual Call Point
    $68.74 $87.99

© 2026 - SPAAR-VOOR-EURIES.NL